Tape Photoluminescent, Green Diagonal 40mmx10m
When used as part of a low location lighting system, the installer must ensure that there is suf cient ambient light available to activate the tape to attain the required performance.
IMPA Emniyet Ekipmanları — Emniyet Ekipmanları, ShipsBay üzerinde IMPA kodlu tedarik için 4,757 aktif ürün içeren bir gemi ikmal bölümüdür. Bölüm, aralarında Liferafts and Life Boats, Life Jackets / Lifebuoys, Safety Equipment...
IMPA Emniyet Ekipmanları, ShipsBay kataloğunda yapılandırılmış teklif talebi akışları için 4,757 deniz ikmal ürününü bir araya getirir. Alıcılar doğru ürünü IMPA kodu, ürün adı, SKU veya ölçü birimiyle bulur, farklı departmanlardan miktarları toplar ve tek bir toplu teklif talebi gönderir. Her kayıt tarafsız biçimde tanımlanır; satış ekibi stok durumunu, teslim limanını ve ticari koşulları yanıtında doğrular.
Tape Photoluminescent, Green Diagonal 40mmx10m
When used as part of a low location lighting system, the installer must ensure that there is suf cient ambient light available to activate the tape to attain the required performance.
Tape Photoluminescent, Green Diagonal 80mmx10m
When used as part of a low location lighting system, the installer must ensure that there is suf cient ambient light available to activate the tape to attain the required performance.
Tape Photoluminescent, Red Diagonal 40mmx10m
When used as part of a low location lighting system, the installer must ensure that there is suf cient ambient light available to activate the tape to attain the required performance.
Tape Photoluminescent, Red Diagonal 80mmx10m
When used as part of a low location lighting system, the installer must ensure that there is suf cient ambient light available to activate the tape to attain the required performance.
Tape Photoluminescent, Wayfinding 40mmx10m
When used as part of a low location lighting system, the installer must ensure that there is suf cient ambient light available to activate the tape to attain the required performance.
Tape Photoluminescent, Wayfinding 80mmx10m
When used as part of a low location lighting system, the installer must ensure that there is suf cient ambient light available to activate the tape to attain the required performance.
Tape Pipe #2130 Iso 14726 &, Bs1710 Flow Arrows 50mmx30m
Pipelines should be marked at least once in each room; at each penetration point in bulkheads and decks, close to each valve and within a distance of 3 - 5m along the length of the pipeline. Local conditions may require more marking due to pipe bends or the close proximity of pipes for different services. Prior to application, pipes should be dust and oil free. The tape should overlap by at least 20mm on the ‘blind side’ of the pipe, however on pipes with an external circumference of over 200mm the tape only needs to cover half the circumference of the pipe.
Tape Pipe Identification #2101, Bs 1710 Green W150mmx30mtr
Pipelines should be marked at least once in each room; at each penetration point in bulkheads and decks, close to each valve and within a distance of 3 - 5m along the length of the pipeline. Local conditions may require more marking due to pipe bends or the close proximity of pipes for different services. Prior to application, pipes should be dust and oil free. The tape should overlap by at least 20mm on the ‘blind side’ of the pipe, however on pipes with an external circumference of over 200mm the tape only needs to cover half the circumference of the pipe.
Tape Pipe Identification #2102, Bs 1710 Silver/grey W150mmx30m
Pipelines should be marked at least once in each room; at each penetration point in bulkheads and decks, close to each valve and within a distance of 3 - 5m along the length of the pipeline. Local conditions may require more marking due to pipe bends or the close proximity of pipes for different services. Prior to application, pipes should be dust and oil free. The tape should overlap by at least 20mm on the ‘blind side’ of the pipe, however on pipes with an external circumference of over 200mm the tape only needs to cover half the circumference of the pipe.
Tape Pipe Identification #2103, Bs 1710 Brown W150mmx30mtr
Pipelines should be marked at least once in each room; at each penetration point in bulkheads and decks, close to each valve and within a distance of 3 - 5m along the length of the pipeline. Local conditions may require more marking due to pipe bends or the close proximity of pipes for different services. Prior to application, pipes should be dust and oil free. The tape should overlap by at least 20mm on the ‘blind side’ of the pipe, however on pipes with an external circumference of over 200mm the tape only needs to cover half the circumference of the pipe.
Tape Pipe Identification #2104, Bs 1710 Yellow Ochre 150mmx30m
Pipelines should be marked at least once in each room; at each penetration point in bulkheads and decks, close to each valve and within a distance of 3 - 5m along the length of the pipeline. Local conditions may require more marking due to pipe bends or the close proximity of pipes for different services. Prior to application, pipes should be dust and oil free. The tape should overlap by at least 20mm on the ‘blind side’ of the pipe, however on pipes with an external circumference of over 200mm the tape only needs to cover half the circumference of the pipe.
Tape Pipe Identification #2105, Bs 1710 Violet W150mmx30mtr
Pipelines should be marked at least once in each room; at each penetration point in bulkheads and decks, close to each valve and within a distance of 3 - 5m along the length of the pipeline. Local conditions may require more marking due to pipe bends or the close proximity of pipes for different services. Prior to application, pipes should be dust and oil free. The tape should overlap by at least 20mm on the ‘blind side’ of the pipe, however on pipes with an external circumference of over 200mm the tape only needs to cover half the circumference of the pipe.
Tape Pipe Identification #2106, Bs 1710 Light Blue 150mmx30mtr
Pipelines should be marked at least once in each room; at each penetration point in bulkheads and decks, close to each valve and within a distance of 3 - 5m along the length of the pipeline. Local conditions may require more marking due to pipe bends or the close proximity of pipes for different services. Prior to application, pipes should be dust and oil free. The tape should overlap by at least 20mm on the ‘blind side’ of the pipe, however on pipes with an external circumference of over 200mm the tape only needs to cover half the circumference of the pipe.
Tape Pipe Identification #2107, Bs 1710 Black W150mmx30mtr
Pipelines should be marked at least once in each room; at each penetration point in bulkheads and decks, close to each valve and within a distance of 3 - 5m along the length of the pipeline. Local conditions may require more marking due to pipe bends or the close proximity of pipes for different services. Prior to application, pipes should be dust and oil free. The tape should overlap by at least 20mm on the ‘blind side’ of the pipe, however on pipes with an external circumference of over 200mm the tape only needs to cover half the circumference of the pipe.
Tape Pipe Identification #2108, Bs 1710 Orange W150mmx30mtr
Pipelines should be marked at least once in each room; at each penetration point in bulkheads and decks, close to each valve and within a distance of 3 - 5m along the length of the pipeline. Local conditions may require more marking due to pipe bends or the close proximity of pipes for different services. Prior to application, pipes should be dust and oil free. The tape should overlap by at least 20mm on the ‘blind side’ of the pipe, however on pipes with an external circumference of over 200mm the tape only needs to cover half the circumference of the pipe.
Tape Pipe Identification #2111, Bs 1710 Red W50mmx30mtr
Pipelines should be marked at least once in each room; at each penetration point in bulkheads and decks, close to each valve and within a distance of 3 - 5m along the length of the pipeline. Local conditions may require more marking due to pipe bends or the close proximity of pipes for different services. Prior to application, pipes should be dust and oil free. The tape should overlap by at least 20mm on the ‘blind side’ of the pipe, however on pipes with an external circumference of over 200mm the tape only needs to cover half the circumference of the pipe.
Tape Pipe Identification #2112, Bs 1710 Primrose W50mmx30mtr
Pipelines should be marked at least once in each room; at each penetration point in bulkheads and decks, close to each valve and within a distance of 3 - 5m along the length of the pipeline. Local conditions may require more marking due to pipe bends or the close proximity of pipes for different services. Prior to application, pipes should be dust and oil free. The tape should overlap by at least 20mm on the ‘blind side’ of the pipe, however on pipes with an external circumference of over 200mm the tape only needs to cover half the circumference of the pipe.
Tape Pipe Identification #2113, Bs1710 Auxiliary Blue 50mmx30m
Pipelines should be marked at least once in each room; at each penetration point in bulkheads and decks, close to each valve and within a distance of 3 - 5m along the length of the pipeline. Local conditions may require more marking due to pipe bends or the close proximity of pipes for different services. Prior to application, pipes should be dust and oil free. The tape should overlap by at least 20mm on the ‘blind side’ of the pipe, however on pipes with an external circumference of over 200mm the tape only needs to cover half the circumference of the pipe.
Tape Pipe Identification #2114, Bs 1710 Crimson W50mmx30mtr
Pipelines should be marked at least once in each room; at each penetration point in bulkheads and decks, close to each valve and within a distance of 3 - 5m along the length of the pipeline. Local conditions may require more marking due to pipe bends or the close proximity of pipes for different services. Prior to application, pipes should be dust and oil free. The tape should overlap by at least 20mm on the ‘blind side’ of the pipe, however on pipes with an external circumference of over 200mm the tape only needs to cover half the circumference of the pipe.
Tape Pipe Identification #2115, Bs1710 Emerald Green W50mmx30m
Pipelines should be marked at least once in each room; at each penetration point in bulkheads and decks, close to each valve and within a distance of 3 - 5m along the length of the pipeline. Local conditions may require more marking due to pipe bends or the close proximity of pipes for different services. Prior to application, pipes should be dust and oil free. The tape should overlap by at least 20mm on the ‘blind side’ of the pipe, however on pipes with an external circumference of over 200mm the tape only needs to cover half the circumference of the pipe.
Tape Pipe Identification #2116, Bs 1710 Salmon Pink W50mmx30m
Pipelines should be marked at least once in each room; at each penetration point in bulkheads and decks, close to each valve and within a distance of 3 - 5m along the length of the pipeline. Local conditions may require more marking due to pipe bends or the close proximity of pipes for different services. Prior to application, pipes should be dust and oil free. The tape should overlap by at least 20mm on the ‘blind side’ of the pipe, however on pipes with an external circumference of over 200mm the tape only needs to cover half the circumference of the pipe.
Tape Pipe Identification #2117, Bs 1710 White W50mmx30mtr
Pipelines should be marked at least once in each room; at each penetration point in bulkheads and decks, close to each valve and within a distance of 3 - 5m along the length of the pipeline. Local conditions may require more marking due to pipe bends or the close proximity of pipes for different services. Prior to application, pipes should be dust and oil free. The tape should overlap by at least 20mm on the ‘blind side’ of the pipe, however on pipes with an external circumference of over 200mm the tape only needs to cover half the circumference of the pipe.
Tape Pipe Identification #2118, Bs 1710 Blue W50mmx30mtr
Pipelines should be marked at least once in each room; at each penetration point in bulkheads and decks, close to each valve and within a distance of 3 - 5m along the length of the pipeline. Local conditions may require more marking due to pipe bends or the close proximity of pipes for different services. Prior to application, pipes should be dust and oil free. The tape should overlap by at least 20mm on the ‘blind side’ of the pipe, however on pipes with an external circumference of over 200mm the tape only needs to cover half the circumference of the pipe.
Tape Pipe Identification #2119, Bs 1710 Sea Green W50mmx30mtr
Pipelines should be marked at least once in each room; at each penetration point in bulkheads and decks, close to each valve and within a distance of 3 - 5m along the length of the pipeline. Local conditions may require more marking due to pipe bends or the close proximity of pipes for different services. Prior to application, pipes should be dust and oil free. The tape should overlap by at least 20mm on the ‘blind side’ of the pipe, however on pipes with an external circumference of over 200mm the tape only needs to cover half the circumference of the pipe.
Emniyet Ekipmanları, ShipsBay üzerinde IMPA kodlu tedarik için 4,757 aktif ürün içeren bir gemi ikmal bölümüdür. Bölüm, aralarında Liferafts and Life Boats, Life Jackets / Lifebuoys, Safety Equipment - Additional Items, Lifeboat / Liferaft Accessories, Pyrotechnics, Breathing Apparatus olmak üzere 6 alana ayrılmıştır. Ürünler PCS, SET, PRS, LGH, PKT birimleriyle tedarik edilir ve IMPA kodu, ad ve ölçü birimiyle kataloglanır.
Fiyatlar talep üzerine verilir: ürünü IMPA kodu veya adıyla bulun, teklif sepetine ekleyin ve miktar, ölçü birimi ile teslim limanını belirten tek bir toplu talep gönderin. Kesin özellikler ve stok durumu tedarikçi teklifinde doğrulanır.